Automatic surface (skimmer) blowdown
is an extremely cost effective investment for most boiler
operations. TDS control via skimmer blowdown offers savings from a
variety of sources.
- Energy - Minimizes waste of heated
water
- Water - Increased cycles of
concentration
- Chemicals - Maximizes chemical
effciency
- Equipment Protection - Proper
blowdown control helps keep heat exchange surfaces free of
scale
Description:
The Models B-7M & B-8M controllers from Water Wise of America
Inc. offer an economical boiler control system with the accuracy
and convenience of a meter read-out. Each controller features an
analog dual scale meter display with a switch selectable scale
range 0-3000 or 0-6000 mS.
The Models B-7m & B-8m are
furnished in TPE molded enclosures with padlockable Lexan viewing
windows.
Access holes are provided at the
bottom of the enclosures for electrical connections. Proper
conduit fittings will allow the units to retain a NEMA 4X rating.
Timed Sampling
The Model B-7 controller incorporates a sample timer which allows
the boiler to be sampled at periodic intervals. Sample intervals
are adjustable from approximately 5 minutes to 6 hours. Sample
duration (On-Time) is adjustable from approximately 15 seconds to
5 minutes. As a general rule, timed sampling is used if the
boiler's blowdown requirement is less than 5000 lbs/Hr.
Continuous
Sampling
The Model B-8 controller is designed for continuous sampling of
boilers. This system should be used only when blowdown
requirements are high enough to insure that a continuous sample
does not "over blow" the boiler.
Specifications:
Range: ..................................0-3000, 0-6000 mS
switch selectable
Electrode:..............................Part No. BE-1C, molded
Ryton and stainless steel provided in 1" (2.5cm) cross.
Pressure 250 psi (17.3 bar.) Temperature maximum 400 deg. F (204
deg C), wiring - 1/2" threaded Conduit T.
Accuracy:..............................+/-2%
Drift:......................................Less than .25%/month.
Differential:............................6% factory setting.
Power(input).........................115 VAC, 50/60 HZ. (95-135
VAC)
Control:.................................115 VAC, 5 amp max.
normally open & normally closed contacts provided.
Environment:..........................Ambient temperature
-40-140degree F (-40 - 60 deg C) 0-100% relative humidity.
Elclosure:...............................Molded TPE with
padlockable gasketed Lexan door. Conduit holes provided.
Dimensions:............................8 lbs. (with electrode
assembly).
|